Артикул: Memosens CLS15E
Производитель: Endress+Hauser
Наличие: Под заказ
Цена:
уточняйте у менеджера
Memosens 2.0 contacting conductivity sensor for standard applications in pure and ultrapure waterMemosens CLS15E is perfectly suited for conductivity measurement in applications with low measuring ranges such as boiler feedwater and chip cleaning. The contacting conductivity sensor performs reliably and accurately even in hazardous areas. CLS15E features Memosens 2.0 digital technology, offering extended storage of calibration, adjustment and process data. It facilitates predictive maintenance and provides the perfect basis for IIoT services.Краткие характеристики Memosens CLS15EДиапазон измеренияk=0,01: 0.04 to 20 µS/cm k=0,1: 0.10 to 200 µS/cm
Рабочая температураThreaded with fixed cable:-20 to 100 °C (-4 to 212 °F)Threaded with plug-in head:-20 to 120 °C (-4 to 248 °F)Sterilization: max. 140 °C (284 °F) for 30 minutes
Рабочее давление13 bar at 20 °C (188 psi at 68 °F) absolute1 bar at 120 °C (14 psi at 248 °F) absoluteПодробное описание Memosens CLS15E Преимущества Designed for low maintenance and a long operating life, the sensor offers best value for money.
The sensor is sterilizable and autoclavable, allowing for installation in sterile plants.
Thanks to its electrode geometry, Memosens CLS15E provides reliable and accurate measured values at low conductivities.
A quality certificate stating the individual cell constant enables perfect adjustment of the measuring point.
IIoT ready: Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
Non-contact inductive signal transmission ensures maximum process safety. Область применения
Memosens CLS15E measures conductivity in pure and ultrapure water applications for the monitoring and control of:
Boiler feedwater
Ion exchangers
Reverse osmosis
Cooling water
Distillation
Chip cleaning
The digital sensor can be used in power plants for:
Degassed conductivity
pH measurement with differential conductivity
With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use. Характеристики и спецификации Проводимость Принцип измеренияКондуктивные датчики
ПрименениеMeasurement in pure and ultrapure water rangeMonitoring of ion exchangersReverse osmosisDistillation and chip cleaning
ХарактеристикиDigital 2-electrode conductivity sensor
Диапазон измеренияk=0,01: 0.04 to 20 µS/cmk=0,1: 0.10 to 200 µS/cm
Принцип измеренияConductive conductivity cell with electropolished stainless steel electrodes
Конструкция2-electrode conductivity cell with coaxially arranged electrodes, electropolished
МатериалElectrode: stainless steel 1.4435Electrode shaft: PES
Габаритные размерыElectrode diameter: 16 mm (0.63 ")Electrode length: appr. 55 mm (2.17 ")
Рабочая температураThreaded with fixed cable:-20 to 100 °C (-4 to 212 °F)Threaded with plug-in head:-20 to 120 °C (-4 to 248 °F)Sterilization: max. 140 °C (284 °F) for 30 minutes
Рабочее давление13 bar at 20 °C (188 psi at 68 °F) absolute1 bar at 120 °C (14 psi at 248 °F) absolute
Датчик температурыPt1000
Сертификаты на взрывозащитуATEX, NEPSI, CSA, IECEx, INMETRO, EAC Ex
ПодключениеProcess: 1/2" and 3/4" NPT, Clamp 1 1/2"Sensor connection: Inductive, digital connection head with Memosens 2.0 technology
Степень защитыIP68
Дополнительные сертификатыCalibration certification of the cell constante and temperature, material certification 3.1